Advantages of flushing tilts:
- Low-maintenance
- Reliable
- Proven, widespread technology
- Low energy consumption
- Short, powerful flush
- Multiple rinsing possible
- Little noise
- Small rinse-water consumption
- Standard design method
- Connection of several tilts possible
- Remote-controlled
- Fully automated with AquaControl module
Playlist
0:20
0:29
0:23
| Product | Size | Scope of services | Client/ Contact | Project/ Contact | Completion |
|---|---|---|---|---|---|
| 2 pieces Tipping buckets V= 700 l/m | L= 5.040 mm | Manufacture and assembly | Stadt Versmold 33775 Versmold | Kläranlage Versmold Herr Kortenbreer | 11/2025 |
| 4 pieces Tipping buckets V= 596 l/m | L= 3.790 mm | Manufacture delivery | Prowatec 23, rue de la Gare L-9122 Schieren | RÜB Reckange | 06/2025 |
| 1 piece Tipping buckets V= 600 l/m | L= 7.140 mm | Manufacture and assembly | Klaus Stewering GmbH&Co. KG 46325 Borken Herr Seier | Ahaus Wessum Stadt Ahaus | 03/2025 |
| 2 pieces Tipping buckets V= 392 l/m | L= 4.640 mm | Manufacture delivery | Godina Miroslava Krleze 4 HR-51000 Rijeka | RB Djecka Bolnica Herr Cepic | 01/2025 |
| 4 pieces Tipping buckets V= 392 l/m | L= 3.140 mm | Manufacture delivery | Godina Miroslava Krleze 4 HR-51000 Rijeka | RB CS3Maj Herr Cepic | 01/2025 |
| 6 pieces Tipping buckets V= 100 l/m | L= 6.623 mm | Manufacture and assembly | ESA GmbH 57334 Bad Laasphe | RÜB Locher Str. Technische Betriebe Solingen Herr Perlberg | 11/2024 |
| 4 pieces Tipping buckets V= 1000 l/m | L= 3.180 mm | Manufacture and assembly | Servicebetriebe Neuwied AöR 56564 Neuwied | RÜB Klärwerk 1 Neuwied Herr Grätz | 08/2024 |
| 1 piece Tipping buckets V= 980 l/m | L= 3.640 mm | Manufacture delivery | Biogest AG Siemensstraße 1 65232 Taunusstein | RÜB Essen Nord Herr Hilge | 04/2024 |
| 2 pieces Tipping buckets V= 410 l/m | L= 3.640 mm | Manufacture delivery | Prowatech 23, rue de la Gare L-9122 Schieren | RÜB Contern Herr Druckenmüller | 09/2023 |
| 1 piece Tipping bucket V= 410 l/m | L= 5.640 mm | Manufacture delivery | Godina Miroslava Krleze 4 HR-51000 Rijeka | RB Cantrida Herr Cepic | 08/2023 |
| 4 pieces Tipping buckets V= 159 l/m | L= 2.640 mm | Manufacture and assembly | Technische Betriebe Solingen Herr Langerhans-Mulack | RÜB Ehrener Mühle Solingen | 05/2023 |
| 4 pieces Tipping buckets V= 800 l/m | L= 4.240 mm | Manufacture and assembly | Erftverband Am Erftverband 6 50126 Bergheim | Kläranlage Grevenbroich Herr Bartz | 03/2023 |
| 4 pieces Tipping buckets V= 885 l/m | L= 4.640 mm | Manufacture delivery | WEAG GmbH Am Leitzelbach 23 74889 Sinsheim | Kläranlage Upstadt Weiher | 02/2023 |
| 1 piece Tipping bucket V= 1559 l/m | L= 1.740 mm | Manufacture delivery | WEAG GmbH Am Leitzelbach 23 74889 Sinsheim | Kläranlage Upstadt Weiher | 01/2023 |
| 6 pieces Tipping buckets V= 890 l/m | L= 3.490 mm | Manufacture delivery | Duro GmbH Nauwies 6 66802 Überherrn | Kläranlage Kamp-Lintfort | 11/2022 |
| 1 piece Tipping bucket V= 850 l/m | L= 9.440 mm | Manufacture and assembly | Bremer pro Aqua Am Fallturm 11 28359 Bremen | Kläranlage Würselen Euchen | 03/2022 |
| 2 pieces Tipping buckets V= 205 l/m | L= 4.260 mm | Manufacture delivery | Prowatec 23, rue de la Gare L-9122 Schieren | RÜB W5 Moutfort | 06/2021 |
| 2 pieces Tipping buckets V= 400 l/m | L= 2.650 mm | Manufacture and assembly | Hofschroer Alte Haselünner Str. 5 49808 Lingen | Kläranlage Stadtwerke Wesel | 05/2021 |
| 2 pieces Tipping buckets V=1200 l/m | L= 6.560 mm | Manufacture and assembly | Hofschroer Alte Haselünner Str. 5 49808 Lingen | Kläranlage Stadtwerke Wesel | 05/2021 |
| 2 pieces Tipping buckets V=1400 l/m | L = 6.060 mm | Manufacture and assembly | Hofschroer Alte Haselünner Str. 5 49808 Lingen | Kläranlage Stadtwerke Wesel | 05/2021 |
| 3 pieces Tipping buckets V= 1600 l/m | L= 3.640 mm | Manufacture | Bioenvtech Shanghai | Nanhu | 12/2020 |
| 8 pieces Tipping buckets V= 300 l/m | L= 5.320 mm | Manufacture and assembly | Van Boekel Kroatenstr 53 47623 Kevelar | Essen Hülsenbruch Emscher Genossenschaft Essen | 03/2021 |
| 1 piece Tipping bucket V= 750 l/m | L = 6.840 mm | Manufacture and assembly | Stetter GmbH Im Lettenäcker 4 72202 Nagold | RÜB Reihersteig Stadtentwässerung Reutlingen | 05/2020 |
| 4 pieces Tipping buckets V= 1000 l/m Material 1.4301 | L= 4.520 mm | Manufacture and assembly | Erftverband Am Erftverband 6 50126 Bergheim | RÜB Wevelinghofen Herr Bartz | ca. 06/2019 |
| 6 pieces Tipping buckets V= 2400 l/m Material 1.4301 | L= 4.640 mm | Manufacture and assembly | Lenke Industrieassembly Robert Koch Str. 34 55129 Mainz | RRB Am Linsenberg Herr Grohmann | ca. 04/2019 |
| 2 pieces Tipping buckets V= 596 l/m Material 1.4301 | L= 4.440 mm | Manufacture and assembly | KLAWA Anlagenbau Bahnwiesenweg 6 34281 Gudensberg | RRB Fuldatal Herr Smasal | 03/2019 |
| 2 pieces Tipping buckets V= 350 l/m Material 1.4301 | L= 5.640 mm | Manufacture and assembly | Prowatec Rue de la Gare 23 L -9122 Schieren | Herr Druckenmüller | 01/2019 |
| 1 piece Tipping bucket V=350 l/m | L=4.640 mm | Manufacture | WKS Technik Gasanstaltstr. 10 01237 Dresden | KA Schlösschen Herr Klinger | 10/2018 |
| 2 pieces Tipping buckets V= 1170 l/m Material 1.4301 | L= 4.640 mm | Manufacture and assembly | LINEG Friedrich-Heinrich-Allee 64 47475 Kamp-Lintfort | RÜB Alpen Herr Holzum | 04/2018 |
| 2 pieces Tipping buckets V= 1800 l/m Material 1.4301 | L= 5.440 mm | Manufacture and assembly | KLAWA Anlagenbau Bahnwiesenweg 6 34281 Gudensberg | Kläranlage Marienheide Herr Ludger Kaiser | 08/2016 |
| 2 pieces Tipping buckets V = 700 l/m Material 1.4301 | L = 6.140 mm | Manufacture and assembly | Gemeinde Rosendahl Hauptstraße 30 48720 Rosendahl | Gemeinde Rosendahl Herr Kohnert | 04/2016 |
| 2 pieces Tipping buckets V = 700 l/m Material 1.4301 | L = 6.140 mm | Manufacture and assembly | Gemeinde Rosendahl Hauptstraße 30 48720 Rosendahl | Gemeinde Rosendahl Herr Kohnert | 08/2015 |
| 4 pieces Tipping buckets V = 500 l/m Material 1.4301 | L = 4.890 mm | Manufacture and assembly | Gemeinde Neuler Hauptstraße 15 73491 Neuler | Gemeinde Neuler/ Herr Schmid | 10/2015 |
| 1 piece Tipping bucket V = 596 l/m Material 1.4301 | L = 5.800 mm | Manufacture and assembly | Fecke Tiefbau GmbH An der Trift 9 33154 Salzkotten | STEB Paderborn/ Herr Rammer | 03/2015 |
| 1 piece Tipping bucket V = 600 l/m Material 1.4571 | L = 4.660 mm | Manufacture and assembly | Hochtief Infrastructure GmbH Neusser Straße 155 50733 Köln | RKB Bergisch Gladbach/ Herr Heitmann | 03/2015 |
| 1 piece Tipping bucket V = 700 l/m Material 1.4301 | L = 7.640 mm | Manufacture and assembly | Scheele Metallbau Gbr Hinter den Häfen 6 34477 Berndorf | Metallbau Scheele/ Herr Scheele | 03/2014 |
| 2 pieces Tipping buckets V = 596 l/m Material 1.4301 | L = 4.660 mm | Manufacture and assembly | KLAWA Anlagenbau Bahnwiesenweg 6 34281 Gudensberg | STEB Paderborn/ Herr Rammer | 03/2014 |
| 1 piece Tipping bucket V = 300 l/m Material 1.4301 | L = 3.440 mm | Manufacture and delivery | Auf Anfrage | Penig/ | 11/2013 |
| 8 pieces Tipping buckets V = 470 l/m Material 1.4301 | L = 4.940 mm | Manufacture and delivery | Esot Tech Solwenien | Esot Tech Mr Bostjan Vas | 09/2013 |
| 8 pieces Tipping buckets V = 350 l/m Material 1.4301 | L = 2.640 mm | Manufacture and delivery | Esot Invest Solwenien | Esot Invest Mr Raporta | 08/2013 |
| 1 piece Tipping bucket V = 460 l/m Material 1.4301 | L = 4.640 mm | Manufacture and delivery | Zahnen Technik GmbH Unterstraße 10 54687 Arzfeld | RÜB Mettendorf/ Herr Ademes Tel.: 06550-92900 | 12/2012 |
| 1 piece Tipping bucket V = 300 l/m Material 1.4301 | L = 4.140 mm | Manufacture and delivery | Zahnen Technik GmbH Unterstraße 10 54687 Arzfeld | RÜB Liefrange/ Herr Ademes Tel.: 06550-92900 | 12/2012 |
| 1 piece Tipping bucket V = 720 l/m Material 1.4301 | L = 3.700 mm | delivery and assembly | Stadtentwässerung Hildesheim Kardinal-Bertram-Str. 1 31134 Hildesheim | RÜB Schützenhalle Herr Krüger Tel.: 05121-7458899 | 09/2012 |
| 2 pieces Tipping buckets V = 390 l/m Material 1.4301 | L = 3.640 mm | Manufacture and delivery | Zahnen Technik GmbH Unterstraße 10 54687 Arzfeld | RÜB Senningen/ Herr Ademes Tel.: 06550-92900 | 05/2012 |
| 1 piece Tipping bucket V = 900 l/m Material 1.4301 | L = 5.430 mm | delivery and assembly | AV Langen/Egelsbach/Erzhausen Prinzessin-Magaret-Allee 1 63225 Langen | Langen Egelsbach/ Herr Volpert Tel.: 06103-908412 | 03/2012 |
| 2 pieces Tipping buckets V = 1.440 l/m Material 1.4301 | L = 6.440 mm | delivery and assembly | Hoelschertechnik-gorator GmbH Venneweg 28 48705 Gescher | Heidenheim Mergelstetten/ Herr Oberschelp | 02/2012 |
| Double-tipping buckets V = 2400 l/m Material 1.4301 4 pieces radially floating baffle Material GFK/ 1.4571 | L = 2x 4590 mm L = 4950 mm H = 800 mm | delivery and assembly | Stadtentwässerung Paderborn Pontanusstraße 55 33102 Paderborn | Hans-Humpert-Str./ Herr Rammer | 12/2011 |
| 8 pieces Tipping buckets V = 500 l/m Material 1.4301 2 pieces Tipping buckets V = 500 l/m Material 1.4301 | L = 5.500 mm L = 1.300 mm | Manufacture and delivery | Obiwap International GmbH Gasanstaltstraße 10 01237 Dresden | RÜB Ploiesti/ Herr Schmelzle Tel.: 0351-25088540 | 08/2011 |
| 2 pieces Tipping buckets V = 350 l/m Material 1.4301 | L = 2.990 mm | delivery and assembly | Prowatech 23, rue de la Gare L-9122 Schieren | Lorentzweiler/ Herr Hinkels Tel:+352-3329141 | 06/2011 |
| 2 pieces Tipping buckets V = 350 l/m Material 1.4301 | L = 5.490 mm | Manufacture and delivery | Zahnen Technik GmbH Unterstraße 10 54687 Arzfeld | Schleiwenhaff/ Herr Ademes Tel.: 06550-92900 | 04/2011 |
| 2 pieces Tipping buckets V = 500 l/m Material 1.4301 | L = 7.040 mm | Manufacture and delivery | Aecom Limited Aecom House, 63-77 Victoria Street St. Albans, Herts, AL1 3ER Ireland | Aecom,Ireland/ Mr. Smith Tel.: +3531-4039300 | 10/2010 |
| 1 piece Tipping bucket V = 350 l/m aus Material 1.4571 | L = 7.000 mm | Manufacture and delivery | Stulz-Planaqua GmbH Beim Signauer Schachen 7 79865 Grafenhausen | Lembach/ Herr Thaller Tel.: 07748-9200 20 | 09/2010 |
| 2 pieces Tipping bucket V = 800 l/m Material 1.4301 1 piece radially floating baffle Material GFK | L = 6.890 mm L = 7.250 mm H = 800 mm | Manufacture and delivery | Auf Anfrage | Bernburg/ | 10/2010 |
| 2 pieces Tipping bucket V = 1000 l/m Material 1.4301 | L = 3.890 mm | Manufacture and delivery | Auf Anfrage | Potsdam/ | 10/2010 |
| 2 pieces Tipping buckets V = 450 l/m Material 1.4301 | L = 5.640 mm | Manufacture and delivery | Auf Anfrage | Rochlitz/ | 09/2010 |
| 1 pieces Tipping bucket V = 2000 l/m Material 1.4301 | L = 640 mm | delivery and assembly | Heckmann Bau GmbH& Co KG Gallbergweg 36 59929 Brilon | Rösenbeck/ Herr Schulte 02961-97860 | 10/2010 |
| 3 pieces Tipping buckets V = 550 l/m Material 1.4301 1 piece radially floating baffle Material 1.4301 | L= je 4.840 mm L= je 15.000 mm H = je 800 mm | Manufacture and delivery | Auf Anfrage | Chemnitz, LU 4/ | 06/2010 |
| 3 pieces Tipping buckets V = 350 l/m aus Material 1.4301 | L= je 5.140 mm | Manufacture and delivery | Auf Anfrage | Oederan, RÜB / | 06 / 2010 |
| 1 piece Tipping bucket V = 400 l/m Material 1.4301 | L= 3.640 mm | Manufacture and delivery | Metallbau Scheele Hinter den Höfen 34744 Twistetal | KA Medebach Herr Müller Tel.: 0171 3 33 91 67 | 10 / 2009 |
| 1 piece Tipping bucket V = 500 l/m Material 1.4301 1 piece baffels Aqua-Skim fix Material 1.4301 | L= 5.600 mm L= 2.800 mm H= 1350 mm | Manufacture and delivery | Otto Schatte GmbH Hochstraße 82 23554 Lübeck | Stadtbetrieb Reinbek, RKB Reinbeck/ Herr Koth Tel.: 0451-4088028 | 09 / 2009 05/2010 |
| 3 pieces Tipping buckets V = 400 l/m Material 1.4301 | L= je 7.750 mm | Manufacture and delivery | Auf Anfrage | Stadt Leipzig, KA Wahren/ | 07 / 2009 |
| 6 pieces Tipping buckets V = 1400 l/m Material 1.4301 | L= je 4.440 mm | Manufacture and assembly | Syro System-Rohr and Anlagenbau GmbH Schmiedestraße 3 57234 Wilnsdorf | Kasseler Entwässerungs-betriebe, RRB Teichbreite / Herr Dormann, Tel.: 02737-9851 11 | 04 / 2009 |
Specification Text AquaFlush Tipping Bucket
Sample specification for planners and specifiers. Ready to be adopted into your bill of quantities.
AquaFlush Tipping Bucket – Flush Cleaning System
Proof of delivery:
SGS Aqua Technologies GmbH
Burmeckestraße 4–6, D-59955 Winterberg
Tel.: +49 2983 974268-0
Fax: +49 2983 974268-68
Consisting of
- Tipping bucket trough with statically sufficient internal bracing.
Dimensions: for clear tank width ______ m, L = ______, V = ______ l/m
Material: Stainless steel 1.4301 - 2 brackets for dowelling to the level, vertical building wall, incl. 2 rubber buffers and one plain bearing per bracket.
Material: Stainless steel 1.4301 - Mounting material consisting of the necessary stainless steel screws, dowels and other system-related small parts
Functional description
The tipping bucket must be designed in such a way that it remains in its initial position during the filling process. Shortly before the maximum fill level is reached, the torque of the bucket must shift and thereby trigger the flushing process. The automatic return of the bucket to its initial position must take place with a minimum of noise development and impact torque.
Item
| Pos. | Description | Quantity / Unit | Unit price | Total price |
|---|---|---|---|---|
| 1. | AquaFlush tipping bucket flush cleaning system – supply and installation | 1,000 pc | ____________ | ____________ |
Sample specification text SGS Aqua Technologies GmbH · Version 02.05.2014 · All information without guarantee. For questions on the technical design please contact our sales department directly.
Frequently asked questions about the automated Aqua-Flush tipping bucket flusher
Answers on how the Aqua-Flush tipping bucket flusher works, its advantages over manual flushing, its applications, control, standards, materials, retrofitting and maintenance. Is your structure not covered here? Write to us and we will look at your case.
What is the automated Aqua-Flush tipping bucket flusher?
The Aqua-Flush tipping bucket flusher is a fully automated system for flush wave cleaning in wastewater facilities. It removes deposits and sediment from the basin floor in an energy-efficient way and keeps maintenance to a minimum thanks to its simple design.
What advantages does the Aqua-Flush offer compared with manual solutions?
The Aqua-Flush increases efficiency through automated flushing cycles. It reduces the workload for personnel, minimises downtime and ensures a consistent flushing quality in line with the German DWA guidelines.
Which applications is the tipping bucket flusher suitable for?
The Aqua-Flush is used in wastewater treatment plants, stormwater overflow tanks and sewer systems. It suits municipal and industrial operators that need reliable flush wave cleaning.
How is the tipping bucket flusher controlled?
Control is handled by sensors and a central control unit. Integration into an existing supervisory control system is possible as an option. The control unit starts filling the Aqua-Flush once the basin has been emptied. The Aqua-Flush tipping bucket empties itself and returns to its home position on its own.
Which standards and norms does the Aqua-Flush comply with?
As the Aqua-Flush tipping bucket flusher is a welded construction, it is manufactured in-house in accordance with DIN EN ISO 3834-3 and DIN EN 1090.
Does SGS Aqua Technologies GmbH also offer maintenance for the tipping bucket flusher?
Yes. We offer maintenance and inspection work for all components of the Aqua-Flush tipping bucket flusher. This covers inspections, servicing and repairs for a long service life.
Can the tipping bucket flusher be retrofitted?
Yes. The Aqua-Flush tipping bucket flusher is designed as a retrofit solution for existing facilities. We survey your existing structure and prepare the required hydraulic design. If modifications to the structure turn out to be necessary, we point them out and support you in carrying them out
Which materials are used for the Aqua-Flush tipping bucket flusher?
The Aqua-Flush tipping bucket flusher is made of corrosion-resistant stainless steel. The material is selected according to the customer’s specifications. The most frequently used grades are X5CrNi18-10 (V2A) and X6CrNiMoTi17-12-2 (V4A).